Rectangular footing pressure
- Input
- 2 m x 1.5 m footing, axial load 900 kN, moment 120 kN-m, load factor 1.5.
- Method
- Compute area, design load, eccentricity, and pressure range.
- Formula
- qmax = P/A x (1 + 6e/B)
- Intermediate steps
- Area = 3 m^2.
- Design load = 1350 kN.
- Eccentricity = 0.133 m.
- qmax = 690 kPa and qmin = 210 kPa.
- Final result
- The pressure stays positive in this simplified example.
- Interpretation
- Useful before comparing with allowable bearing capacity.
- Limitation
- Does not check settlement, punching, reinforcement, or uplift design.